Prostar UPS System

GT200K three phase 200kva ups system

 Prostar GT200K three phase 480Vdc large medical grade 200kva ups system offers technology that increases performance and reliability. Online technology fully isolates and protects against all power quality disturbances. The upstream harmonics management allows a generator friendly installation and flexible configurations for even the most demanding designs.



GT200K three phase 480Vdc large medical grade 200kva ups system offers features such as paralleling capability for N+1 or N+X redundancy, full front access, included start up for ease of serviceability, user friendly graphical display with multiple language options, and SNMP with network based power management options.

Hospitals are the core of community response in an emergency. In the event of a power outage, a reliable UPS system can protect patients, staff, and data alike to maintain a hospital’s high efficiency and critical functions running without interruption.

Prostar UPS for hospital and medical system providers adhere to the most stringent safety standards. By ensuring zero downtime for the entire electrical system, Prostar UPS helps the heart of hospital beating all the time.

ups uninterruptible power supply

Prostar uninterruptable power supply is industry-leading efficiency, availability, and performance for small, medium, large data centers and mission critical environments.

200KVA UPS System

residential ups systems

Online UPS Backup Systems Details

UPS Backup Systems

UPS LCD Display

Industrial Online UPS Internal Structure

UPS Free Monitoring anytime and anywhere

3 Phase Online UPS is designed to meet the toughest product customization requirements for specific mechanical protection degree. A 3:1 crest factor safely supports a variety of loads, even those with wildly fluctuating power demands.

three phase igbt online ups

200KVA UPS System Specification

ModelGT200K
Capacity200KVA/160KW
UPS Efficiency>95%
Noise48dB~54dB(Distance 1 Meter)
Dimension(WxDxH mm)1420x750x1805
Weight(Kgs)1210
INPUT
Voltage3 Phases 4 Wires, 380Vac/400Vac/415Vac ± 25%
Frequency50Hz/60Hz±5% (Automaticly)
Power Factor≥0.95
OUTPUT
Voltage3 Phases 4 Wires, 380Vac/400Vac/415Vac ± 1%
Frequency50Hz/60Hz±0.05%(By Battery)
Harmonic DistortionLinear load<3%, Non-linear load<5%
Imbalance VoltageBalance load≤1%, Imbalance load≤3%
Phase Shif AngleBalance load≤1°, Imbalance load≤2°
Transient ResponseOutput at 0~50%~100% ≤5%, response ≤ 10ms
Overload Capacity110%≥300Min, 125%≥10Min, 150%≥1Min
Crest Factor3:1
Wave FormPure sine wave
Transfer Time0ms
BATTERY
TypeSupport VRLA Battery
D.C. Voltage480Vdc
Max. Charging Current0.2AxC10
Charging Time(Standard)12hours
SYSTEM
ProtectionInput over-voltage, under-voltage; output overload, shortcircuit; Inverter over-temperature; Battery under-voltage,over-voltage
IP ProtectionIP20
Parallel ModeN+1,N+X,can be in parallel with differenct power capacity
Software InterfaceWindows9x,2000,NT,ME,XP,Linux,Novell,Macosx,NT4.0
Meantime Between Failures300,000Hours
ENVIRONMENT
Operating Temperature0℃ to 40℃
Humidity0~95% (non-condensing)
Altitude<1000m (with increase of 100m,it will reduce output of 1%) max. 4000m
Storage Temperature-15℃ to 50℃
Safety complianceEN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU
EMC conformanceEN 62040-2 and Directive 2014/30/EU
MANAGEMENT
Communication InterfaceRS232/RS485
Remote SignalingDry contact (battery low,battery discharging,bapass/fault),EPO
Remote ControlEPO and bypass
SNMPPower managemetn from SNMP manager and web browser
OptionalDustproof & dampproof, Isolating inverter transformer, lightning surge absorption, static switches, manual maintainence switch
.