Prostar ET20K LV 3 phase 208v double conversion 20kva industrial ups system helps maintain your enterprise-wide networks, data centers, mission-critical systems and industrial manufacturing processes.
ET LV 208V three-phase uninterruptible power supply delivers top performance for edge, small, and medium data centers, as well as critical infrastructure in commercial and industrial facilities. Its compact design, high-density technology, N+1 redundancy, and fault-tolerant architecture maximize availability, operational efficiency, and critical load protection, while minimizing total cost of ownership.
Best 3 phase 208v double conversion 20kva industrial ups system is up to seven percent more efficient than other UPSs in its class, helping to keep your operating costs down.
A manual bypass breaker as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power if the UPS requires maintenance.
20KVA UPS Features & Benefits
1. Wide input voltage range and frequency range
Designed for harsh electrical environments to save battery life, and suitable for fuel generators or other power generation equipment.
2. Most advanced and high frequency DSP technology
High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology create low input Total Harmonic Distortion (THDi).
3. Super overload capacity
Long-time working under the load of less than 105%; switching to the bypass in 10min under the load of 105% (inclusive) to 125%; switching to the bypass output in 1min under the load of 125% (inclusive) to 150%.
4. Multi-communication Interface
It offers RS232, USB, RS485, CAN, NET, input and output dry contacts, SNMP board, WIFI board, GPRS board and 4G board to monitor the operating status of UPS.
5. Parallel-redundant capable
Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy and share the common battery packs to reduce the cost.
6. Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
7. Cold start and mains start without battery
In the abnormal state of the utility power, the UPS can be started directly with the battery to meet emergency needs.
There is no battery, the UPS can be started directly from the mains power.
8. Lithium-ion batteries compatible
It must be set up separately, not included in the standard configuration.
Industrial UPS System Details
ET LV Series 208V Online UPS Front Panel
ET LV Series 208V UPS Real
20kva industrial ups system Specification
Model | ET20K LV |
Capacity | 20KVA/16KW |
Topology | Double conversion online |
Noise | <65dBA front side 1M |
Dimension(WxDxH mm) | 500x800x1300 |
Weight(Kgs) | 260 |
INPUT | |
Input Rated Voltage | 3P + N + PE, 208Vac/220Vac(L-N: 120Vac/127Vac) |
Input Voltage Range | 167Vac – 250Vac |
Input Rated Frequency | 50Hz/60Hz (Auto) |
Input Frequency Range | 40Hz – 70Hz |
Input Power Factor | >0.95 |
Input Current Limit | 1.25 times Rated INPUT Current (Settable 0.1 – 1.25) |
THDI | < 3% full load |
BYPASS INPUT | |
Bypass Input Voltage Range | 167Vac – 250Vac |
Bypass Input Voltage Regulation | Upper Limit: default 20% (Settable 10%/15%/20%/25%) Lower Limit: default 20% (Settable 10%/20%/30%/40%/50%/60%) |
OUTPUT | |
Output Rated Voltage | 3P + N + PE, 208Vac/220Vac ± 1% (L-N: 120Vac/127Vac) |
Output Voltage Regulation | 0V(Settable ±1V- ±5V) |
Output Frequency | Mains Mode: tracking BYPASS Input in synchronized state Battery Mode: 50Hz/60Hz±0.01% |
Output Power Factor | 0.8 |
Total Harmonic Distortion (THDU) | < 2% at 100% linear load; < 5% at 100% non-linear load |
Overload Capacity | Supports up to 105% load continuously in double conversion; 105% – 110% load for 60 minutes switching to bypass output; 110% – 125% load for 10 minutes switching to bypass output; 125% – 150% load for 1 minute switching to bypass output; greater than 150% load for 200 milliseconds switching to bypass output |
Crest Factor | 3:1 |
Wave Form | Pure sine wave |
Transfer Time | 0ms |
ECO MODE | |
Bypass Output Voltage Regulation | Upper Limit: default 5% (Settable 5%/10%/15%) Lower Limit: default 5% (Settable 5%/10%/15%) |
Bypass Output Frequency Regulation | Default ±2Hz (Settable ±1Hz/±2Hz/±3Hz) |
EFFICIENCY | |
Efficiency at full load (AC-AC) | >93% |
Efficiency at ECO Mode | >98% |
BATTERY | |
Battery Type | Support VRLA Battery, (Lithium-ion Battery Option) |
Battery Voltage | Default 360Vdc (Settable 336VDC/348VDC/372VDC/384VDC) |
Battery Charging Current | Charging Rate * Battery Capacity * Group of Battery (Settable for charging rate, battery capacity and group of battery) |
SYSTEM | |
Protection | Output short circuit protection, output overload protection, over-temperature protection, low battery voltage protection, output overvoltage / undervoltage protection, fan failure protection |
IP Protection | IP30 |
Number of Parallel | < 8 Units |
Cooling Method | Fans |
Display | 7-inch LCD Touch Screen |
Audible Alarm | Audible and visible alarms prioritized by severity |
ENVIRONMENT | |
Operating Temperature | 0℃ to 40℃ (32F-104F) |
Humidity | 0~95% (non-condensing) |
Altitude | < 1000m (Capacity de-rates by 1% for every 100m over 1000m) |
Storage Temperature | -20℃ to 70℃ |
COMMUNICATION | |
Communication Interface | Default: RS232/RS485/USB/Dry Contact/EPO (Option: Battery Temperature Compensation) |
Communication Slot | SNMP/Web interface |
The Articles You May Like
- Which best inverter is good for home use?
- Uninterruptible Power Supply UPS Brochure
- Uninterruptible power supply – Wikipedia
- Know when you need to update your dc to ac inverter
- What are the different types of solar battery?
- You should know the difference between ups and an inverter
- SU2K medical grade 2000va ups power
0 Comments